Ozone is a powerful oxidizing agent that quickly removes a wide range of organic substances and pathogens and is widely used in water treatment, medical disinfection, and air disinfection. Ozone is used for disinfection and is decomposed into oxygen without causing secondary pollution. The ozone generator system is a device for producing ozone and is used wherever ozone is used. ozone water generators are used in water, sewage, industrial oxidation, and space sterilization. The ozone water generator is used in a wide range of applications including water, sewage, industrial oxidation, and space sterilization. Here we will look at the use and installation of the ozone water generator.

Here is the content list:

l Instructions for the use of the ozone water generator.

l What should I pay attention to when installing an ozone water generator?

Instructions for the use of the ozone water generator.

Firstly, the electrolysis ozone generator must be installed and serviced by a trained technician. Secondly, when applying the ozone machine to remove bacteria, it is forbidden to work in a natural environment with high concentrations of activated oxygen and the workplace. Third, bear in mind that the machine and equipment maintenance or overhaul to solve the switching power off and the active oxygen lagoon gas situation to carry out can be very good to ensure the safety of staff overhaul. Fourth, if there is an abnormality, please immediately turn off the power or notify the technical professional staff to carry out maintenance. Fifthly, a standardized and specialized electrical connection, a reliable earthing device, and installation in dangerous areas where nitrogen dioxide is likely to leak or where there is a risk of explosion are strictly forbidden. Sixthly, the production process of the ozone water generator should be understood by the operator and the staff should be able to operate the disinfector skillfully. Seventh, if active oxygen leaks must first turn off the ozone water generator, open the ventilation cooling equipment to carry out natural ventilation to solve the problem, and then withdraw from the ozone water generator application indoor space in time, and wait for the residual active oxygen in the indoor space to drop to the safe category before entering.

What should I pay attention to when installing an ozone water generator?

The installation of the electrolysis ozone generator on site is one of the most fundamental factors affecting the successful operation of future deep treatment systems. As ozone is a strong corrosive gas, it is second only to fluorine in terms of its oxidizing properties in nature. When ozone >100 mg/L is present in the environment it can cause unrecoverable harm to the human body, so the quality of the installation not only affects the successful operation of the system but also has an extremely important impact on the working environment and personal safety. Therefore, the installation of the ozone water generator should pay attention to the following elements.

Firstly, at present, the scale of water plants is basically above 100,000 m3 / d. The single unit of ozone water generator used is often above 10 kg / h, so the transport and lifting of the equipment must be considered as well as the positioning work. Secondly, the installation of the pipework must be carried out by the pipework drawings. Pipes and valves must be fixed with appropriate supports, which are sufficient in number and strength. Thirdly, when processing and installing pipework, it is important to ensure that there is a clean pipework system that is free from contamination by oil, grease, dust particles, etc. Processed fittings must be plugged at their ends and then stored in a dry and clean place; installed pipelines must also be protected at their open ends at all times to avoid dirt and debris entering.

Fourthly, valves and instruments should be installed immediately after opening the packaging; this is particularly important for precision equipment that has been cleaned. Fifthly, the suction and ventilation inlets and outlets on the pipework should be suitably protected from rain, dirt, or small birds and insects. This is generally done by adding a windscreen and a screen made of a material suitable for pipework. Sixthly, inert welding must be used to weld the pipeline. V-weld gaps must be welded properly, with a smooth surface over the root area of the weld. All welds shall be non-destructively tested and the quality of the weld shall comply with the relevant standards. Seventhly, as both oxygen and ozone-containing oxygen pose a fire and life hazard, all gas lines are required to be pressure-sealed tested. Eighthly, attention should be paid to the installation level of the ozone aeration head and the cleanliness of the aeration tube installation during installation. Ninth, it is recommended to install a gas filter at the inlet end of the ozone water generator discharge tank, which is essential to protect the discharge tube.

If you are interested in our ozone generator water purifier products or have other needs, you can contact us at https://www.deposon.com/, we welcome your visit and look forward to working with you.


About Deposon
Guangzhou Deposon Electric Co., Ltd. is a world-leading manufacturer of the fourth - generation "ultimate semiconductor material" – conductive diamonds. It is China's first national high - tech enterprise to bring these diamonds from the laboratory stage to large-scale commercialization.

QUICK LINK

PRODUCT CATEGORY

CONTACT INFO
Guangzhou Deposon Electric Co., Ltd.
  8th Floor, B4 Bldg, 11 Kaiyuan Ave, Guangzhou Science City, China
  +86-20-32077727 ext.816
  info@deposon.com
 
粤ICP备15117742号      Copyright © 2011 - 2021 DEPOSON. All Rights Reserved